A Unitary Air Conditioning Unit (ACU) is a self-contained system designed to cool, heat, and dehumidify indoor spaces, ensuring comfortable and controlled air conditions. It is widely used in residential, commercial, and industrial settings to regulate temperature and air quality efficiently.
Types of Air Conditioning Units (ACUs):
1️⃣ Window AC Unit – Compact, all-in-one system installed in windows or walls.
2️⃣ Split AC Unit – Consists of an indoor and outdoor unit, offering quiet and efficient cooling.
3️⃣ Packaged AC Unit – A single-unit system ideal for cooling large commercial spaces.
4️⃣ Ducted AC Unit – Integrated into central air systems for whole-building climate control.
5️⃣ Portable AC Unit – Mobile unit with flexible venting, suitable for temporary cooling needs.
6️⃣ VRF/VRV System – Advanced system with multiple indoor units connected to one outdoor unit for precise temperature control.
With a variety of configurations available, ACUs provide tailored cooling and heating solutions for diverse applications! ❄️?

Features
Safety & Reliability ✅
Our units are designed and manufactured in accordance with high industry standards, featuring internationally renowned fully enclosed high-efficiency scroll compressors. Paired with precision-engineered high-efficiency heat exchangers, the system ensures high performance, superior reliability, and precise installation adjustments for maximum safety and adaptability.
Multi-Compression & Independent Cooling Cycles
- Designed with multiple compressors and independent refrigeration circuits, ensuring uninterrupted operation.
- “Load Balancing” Control automatically distributes compressor runtime, extending the unit’s lifespan.
- Multi-system design reduces startup current, minimizing impact on the power grid and enhancing energy regulation.
Versatile Options for Different Needs ?
Our units offer a variety of configurations to meet diverse customer requirements:
✅ Cooling-Only Mode ❄️
✅ Heat Pump Mode ?
✅ Auxiliary Electric Heating Mode ⚡
For installation flexibility:
- Direct Air Discharge with Air Hood ?️
- High Static Pressure Ducted Airflow ?️
These options adapt to different site conditions, making installation more convenient.
User-Friendly Operation ?️
The entire unit series is equipped with a high-intelligence microprocessor control system, ensuring ease of operation and efficient management.
LCD Display with an Intuitive Graphical Interface ?️
- Users can simply tap on-screen icons to access real-time information, modify control settings, and adjust unit parameters with ease.
Easy Maintenance & Servicing ?
Removable Panel Design
- All panels are detachable, allowing quick and easy access to internal components.
- Maintenance and servicing can be performed directly from the front, simplifying daily upkeep and equipment inspections.
Wide Range of Applications ?
Our air-cooled constant temperature & humidity unit is ideal for environments with strict temperature and humidity requirements, including:
Food Processing
Electronics & Precision Manufacturing
Medical & Healthcare Facilities
⚖️ Metrology & Measurement Labs
The standard unit is perfect for large spaces and high-load areas, such as:
Hotels & Resorts
Office Buildings
Schools & Universities
?️ Shopping Malls & Supermarkets
?️ Restaurants & Entertainment Centers
Cinemas & Theaters
Warehouses & Industrial Facilities
Designed for performance, built for reliability. ?

Model Selection Guide
When selecting and ordering an air conditioning unit, users should carefully calculate the cooling capacity required during summer and the heating capacity required during winter. The unit can only effectively control temperature and humidity if the cooling (or heating) load does not exceed its rated capacity.
Key Considerations for Model Selection ✅
1️⃣ Performance Parameters & Adjustments
- The performance parameter table provides the nominal cooling capacity and airflow of the unit.
- If the actual operating conditions differ from the nominal conditions, adjustments must be made accordingly.
2️⃣ Air Duct Resistance Matching
- The resistance of the air supply duct should be matched with the external static pressure of the air conditioning unit.
3️⃣ Installation Requirements for Air-Cooled Units
- The height difference between the outdoor and indoor units should be ≤ 20m.
- The connection pipe length should be ≤ 30m.
- The outdoor unit should not be installed below the indoor unit to prevent:
- Insufficient cooling capacity
- Poor compressor oil return, which may lead to severe damage or burnout.
4️⃣ Left-Hand vs. Right-Hand Piping Configuration
- Facing the front of the unit, if the piping connection is on the left, it is a left-hand model; if on the right, it is a right-hand model.
- The standard configuration is left-hand; if a right-hand model is required, please specify this when ordering.
5️⃣ Heating Options
- The default heating method is electric heating.
- If steam coil heating or hot water coil heating is required, please specify when ordering.
6️⃣ Control Panel & Temperature/Humidity Sensors
- The control panel and temperature/humidity sensors are inside the unit by default.
- If they need to be installed externally, please specify the following details when ordering:
a. Wiring distance between the control panel and the unit.
b. Placement of the temperature/humidity sensors (inside the room or in the return air duct).
c. Wiring distance between the sensors and the unit.
7️⃣ Fresh Air Intake Considerations
- Excessive fresh air intake affects temperature and humidity control accuracy.
- If the fresh air ratio exceeds 15%, please specify when ordering.
8️⃣ Special Requirements (Specify When Ordering)
- Centralized computer control or remote monitoring.
- Customized unit dimensions.
- Pre-installed fresh air intake connection.
- Compressor placement inside the indoor unit.
9️⃣ Cooling Load Estimation for Certain Buildings
- For specific building types, additional cooling load calculations may be required to ensure optimal performance.
Ensuring proper model selection and installation is crucial for efficient system operation. Contact us for further consultation! ?